BROAG AVENTA *INTERMITTENT E4,E5*

4 posters

Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty BROAG AVENTA *INTERMITTENT E4,E5*

Post  tommy nash Mon Feb 15, 2010 9:46 am

After replacing 2 ignition transformers and 1 electrode , i was starting to doubt the main pcb, after speaking to tech at broag, they advised to replace burner seal . (s100308) and we do have this in vanstock.
tommy nash
tommy nash

Posts : 6
Join date : 2010-02-12

Back to top Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty Re: BROAG AVENTA *INTERMITTENT E4,E5*

Post  raggie1 Tue Feb 16, 2010 11:21 am

usually those three parts will cure the problem but always check Co2 as will cause fault on low burn i.e CH also I have had this problem occur will a faulty gas valve.

raggie1

Posts : 3
Join date : 2010-02-16

Back to top Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty Re: BROAG AVENTA *INTERMITTENT E4,E5*

Post  Rich S Wed Feb 17, 2010 1:04 am

anyone else have problems adjusting the offset screw for the low fire now they put the red seal over the allen screw?

Rich S
Admin

Posts : 17
Join date : 2009-11-19

https://npht.board-directory.net

Back to top Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty Re: BROAG AVENTA *INTERMITTENT E4,E5*

Post  tommy nash Wed Feb 17, 2010 1:17 pm

i have ,i had to change a gas valve once ,because the installer try'd to change c02 and rounded off the top of it. i find that if i poke it with braddle spike usually chips away.
tommy nash
tommy nash

Posts : 6
Join date : 2010-02-12

Back to top Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty Re: BROAG AVENTA *INTERMITTENT E4,E5*

Post  Rich S Wed Feb 17, 2010 1:45 pm

I spoke to Broag today about one that's had 2 transformers, electodes and burner seal for an E5. Steady 8.8% co2 but I could see the ionisation current dropping to as low as 1.9. They said to watch the 02 level if that was around 5.5% replace the ignition transformer again.

Rich S
Admin

Posts : 17
Join date : 2009-11-19

https://npht.board-directory.net

Back to top Go down

BROAG AVENTA *INTERMITTENT E4,E5* Empty Re: BROAG AVENTA *INTERMITTENT E4,E5*

Post  PALLEN77 Thu Feb 18, 2010 7:33 am

If its on a vertical flue, check co2 with case on. I have had 2 now that was ok with case off, but when the case went back on the co2 went of the scale and locked up my fga. Spoke to broag, it is caused by the inner flue seals split or pushed out, also noticed signs of condense running into boiler from vertical flue. Passed back to installer. Very Happy
PALLEN77
PALLEN77

Posts : 1
Join date : 2010-02-11

Back to top Go down