Broag Avanta range diverter valve passing into C.htg
When changing a diverter valve that is passing into the heating circuit the return isolation valve should be removed to check for debris stuck in isolation valve, if this is not checked the same problem will occur as the debris will end up stuck in the diverter valve again.